| Show Centre and Head Office | | 33-35 Brecon Road | | Abergavenny NP7 5UH | | Call FREE 0800 525966 | |  |   |  | | (C)1982-2008 HERONHURST | | Design & Concept by Andy Hill | | | We cover Wales and the West Country - Abergavenny, Aberystwyth, Bargoed, Barry, Bath, Blackwood, Brecon, Bristol, Brynmawr, Builth Wells, Caldicot, Cardiff, Caerphilly, Cheltenham, Chepstow, Cirencester, Cwmbran, Devon, Ebbw Vale, Evesham, Forest of Dean, Gloucester, Hereford, Lampeter, Llandrindnod Wells, Llangstone, Llanwern, Llantwit Major, Merthyr Tydfil, Monmouth, Pontypool, Porth, Porthcawl, Portskewett, Port Talbot, Radstock, Stroud, Swansea, Swindon, Tredegar, Weston-super-Mare, Worcester, Undy and more - click here for details of our coverage |
|
| | PRODUCTS> CONSERVATORIES > Designer Bases Technical SpecificationsLess disruption, more flexibility! - Your Garden Virtually Untouched!
- Ready To Use Immediately
- Manufactured in accordance with British Standards

| Footing Specifications - Concrete pads are required at the jacking points. Each pad should be 450mm square and a minimum of 450mm deep on firm subsoil's. On clay, sand or peat subsoil's there should be an additional layer of well compacted hard-core to a depth of 200mm below the concrete
- Pad spacing for Dwarf Wall Conservatories - on the length 2,000mm max, on the depth 2500mm width max
- Pad spacing for Full Height Conservatories - on the length 2,500mm max, on the depth 3,000mm width max
Material Specifications - Outer cill (Dwarf Wall) 65mm x 100mm x 7mm RSA Galvanised
- Ring Beam 80mm x 80mm by 3mm SHS
- Floor Joists (up to 3,000mm deep) 60mm x 40mm x 3mm RHS or (over 3,000mm deep) 80mm x 40mm x 3mm RHS
- Flooring - V313 M/R Chipboard, 18mm thick
- Under Floor Insulation - Jablite polystyrene 50mm thick
Bases can be manufactured to suit any shape or size of conservatory Durabase conservatory bases have been designed to British Standards and comply with Building Regulations. Calculations have been made using BS 6399 (Part 1 1984). Loading for the roof and floors, which are 0.7kN/sq.m. snow loading and 1.5kN/sq.m. (or 1.4kN point load on a 300mm) floor loading from table 5 - "Residential Occupancy Class Type 1". The member design has been made in accordance with BS 449 with the additional requirement that side rail deflection should not exceed 2.00mm This information is correct at time of writing, and due to HERONHURST ongoing programme of product development, subject to change without notice. | 
All HERONHURST product lines now include "Fit and Forget" Technology. Designed for no maintenance after professional installation  | | |
| |
|
|
|
|